| CERTIFICATE OF ANALYSIS
Our latest analysis of Woodbine Spring Water was undertaken by the food & water testing laboratories of Sonic Healthcare Limited (National Association of Testing Authorities Australia Accreditation No. 2178) on 1st June 2004.
The details from the Certificates of Analysis are outlined below. (Originals may be sighted on request).
| Lab Number: 75855783
Sample type: Bore water
Date & time of collection: 31/5/04, 1145
Date & time of testing: 1/6/04, 0700
Collected by client and tested as received. |
| TESTS |
RESULTS |
| pH |
4.8 |
|
|
| Conductivity |
45 |
us/cm |
|
| Sodium |
7.1 |
mg/litre |
|
| Potassium |
0.1 |
mg/litre |
|
| Calcium |
0.2 |
mg/litre |
|
| Magnesium |
0.8 |
mg/litre |
|
| Chloride |
9 |
mg/litre |
|
| Nitrate |
2.4 |
mg/litre |
|
| Sulphate |
<2 |
mg/litre |
(Not Detected) |
| Aluminium |
<0.1 |
mg/litre |
(Not Detected) |
| Lead |
<0.01 |
mg/litre |
(Not Detected) |
| Copper |
<0.01 |
mg/litre |
(Not Detected) |
| Iron (total) |
<0.01 |
mg/litre |
(Not Detected) |


|
| Lab Number: 75855164
Sample type: Bore water
Date & time of collection: 31/5/04, 1145
Date & time of testing: 1/6/04, 0830
Collected by client and tested as received. |
| TESTS |
RESULTS |
| Arsenic |
<0.01 |
mg/litre |
(Not Detected) |
| Barium |
<0.1 |
mg/litre |
(Not Detected) |
| Borate |
<0.1 |
mg/litre |
(Not Detected) |
| Bicarbonate |
4 |
mg/litre |
|
| Calcium |
0.2 |
mg/litre |
|
| Cadmium |
<0.001 |
mg/litre |
(Not Detected) |
| Chemical Oxygen Demand |
<1 |
mg/litre |
(Not Detected) |
| Chlorine (free) |
<0.1 |
mg/litre |
|
| Chromium |
<0.01 |
mg/litre |
(Not Detected) |
| Copper |
<0.01 |
mg/litre |
(Not Detected) |
| Cyanide |
<0.01 |
mg/litre |
(Not Detected) |
| Fluoride |
<0.1 |
mg/litre |
(Not Detected) |
| Lead |
<0.01 |
mg/litre |
(Not Detected) |
| Manganese |
<0.01 |
mg/litre |
(Not Detected) |
| Magnesium |
0.7 |
mg/litre |
|
| Mercury |
<0.001 |
mg/litre |
(Not Detected) |
| Nitrate |
2.4 |
mg/litre |
|
| Nitrite |
<0.1 |
mg/litre |
(Not Detected) |
| Potassium |
0.2 |
mg/litre |
|
| Selenium |
<0.05 |
mg/litre |
(Not Detected) |
| Sodium |
7.5 |
mg/litre |
|
| Sulphide |
<0.01 |
mg/litre |
(Not Detected) |
| Zinc |
<0.01 |
mg/litre |
(Not Detected) |
|
| MICROBIOLOGY REPORT
Lab Number: 75855176
Sample type: Bore water
Date & time of collection: 31/5/04, 1145
Date & time of testing: 1/6/04, 0830
Collected by client and tested as received. |
| TESTS |
RESULTS |
UNITS |
| FAECAL COLIFORM COUNT |
Less than 1 |
colony forming units/100ml |
| FAECAL COLIFORMS NOT DETECTED BY THE METHOD |
| ESCHERICHIA COLI COUNT |
Less than 1 |
colony forming units/100ml |
| ESCHERICHIA COLI NOT DETECTED BY THE METHOD |
| METHODS
* Thermotolerant (Faecal) Coliform Count - Australian Standard 4276.7 -1995 by Membrane Filtration Method
* Escherichia coli Count - Australian Standard 4276.7 -1995 by Membrane Filtration Method |
|
| MICROBIOLOGY REPORT
Lab Number: 75855178
Sample type: Bore water
Date & time of collection: 31/5/04, 1145
Date & time of testing: 1/6/04, 0830
Collected by client and tested as received. |
| TESTS |
RESULTS |
UNITS |
| TOTAL COLIFORM COUNT |
Less than 1 |
colony forming units/250ml |
| TOTAL COLIFORMS NOT DETECTED BY THE AUSTRALIAN STANDARD METHOD |
| PSEUDOMONAS AERUGINOSA COUNT |
Less than 1 |
colony forming units/250ml |
| PSEUDOMONAS AERUGINOSA NOT DETECTED BY THE METHOD |
| METHODS
* Total Coliform Count - Australian Standard 4276.5 -1995 by Membrane Filtration Method
* Pseudomonas aeruginosa Count - Australian Standard 4276.13 -1995 by Membrane Filtration Method |
|
|